BD Biosciences ยท Rhapsody

Sequencing Calculator Simplified: How Many Reads do I Need?

Estimate sequencing read requirements and identify suitable Illumina platforms.



Output Table

The values in the table will include the PhiX percentage of the total reads when the PhiX value is provided.

Sequencing Depth Read Pairs/clusters for Sequencing (Million) Reads Pairs/clusters in GigaBases (GB)
✱100 Cycle Kit ✱150 Cycle Kit 300 Cycle Kit

✱:These kits are not suitable for VDJ (TCR/BCR) assays. Please use 200 cycle kit (minimum) or 300 cycle kit (recommended).


Read Pairs per Library

Per-library breakdown of the read pairs needed for sequencing (in Millions) for each selected assay. Shown when more than one assay is selected. Values are before PhiX; PhiX is applied to the combined table above.

Assay Expected Read Pairs / Cell Read Pairs for Sequencing (Million)
Shallow Moderate Deep Shallow Moderate Deep
Illumina Sequencing Platform with PhiX Recommendation
"Use this kit or flow cell?" is based on the Deep sequencing depth.
Illumina Sequencing Platform and Kit Cycles Kit Million Read Pairs Recommended loading concentration

Note:

  • ** These Illumina sequencers use the reverse complement workflow for the i5, which may not be compatible with WTA library if index 2 is sequenced at 60 cycles, and may cause reduction in sequencing quality or even failure. Please contact your local FAS for more information.
  • *** NovaSeq 100 cycle kit (v1.0 or v1.5) can be used. The 100-cycle kit contains enough reagents for up to 138 cycles.

Description

The description below shows the number of reads per cell used to calculate total reads for sequencing and GB value conversion.
The sequencing depth follows the protocol specification.

  • Shallow Sequencing: Suitable for running a pilot study.
  • Moderate Sequencing: This is the general sequencing read count recommended in the protocol.
  • Deep sequencing: Suitable for customers interested in deper sequencing based on experimental purposes. For example, studying rare variant detection or low-frequency gene detection.

Table of read per cells value based on assay and sequencing depth.
Assay Read Pairs for Sequencing
Shallow Moderate Deep
WTA 10,000 reads 30,000 reads 100,000 reads
AbSeq (Read pairs calculated based on each AbSeq) 300 reads
SMK 600 reads
Targeted 2,000 reads 8,000 reads 10,000 reads
TCR/BCR 5,000 reads 5,000 reads 5,000 reads
ATAC 50,000 reads 50,000 reads 50,000 reads

For wet-lab-related questions, please contact local FAS. For questions about the tool, please contact development team.
Sequencing Calculator (Version3.0.0) | September 2026